文章摘要
Influences of different parameters of return air duct onuniformity distribution of temperature and humiditywithin refrigeration compartment
  
DOI:
Author NameAffiliation
王广海 1, 2 , 吕恩利 2 , 陆华忠 2 , 唐本源 2 1.…广东机电职业技术学院 广东… 广州………510515 2.…华南农业大学南方农业机械与装备关键技术教育部重点实验室 广东… 广州………510642 
Hits: 1521
Download times: 592
Abstract:
      We…changed…the…length, width…and…height…parameters…of…return…air…duct, established…refrigeration… compartment…test…platform, got…on…parameter…combinations…orthogonal…experiments…under…the…same…conditions…of… blower…frequency, opening…bulkhead…opening…rate…and…crate…stacking…method, respectively…conducted…cooling…and… humidification…tests…taking…unevenness…in…longitudinal…section…and…cross…section…as…assessment…indicators, variance… analysis, visual…analysis…and…range…analysis…were…used…to…study…the…influences…of…different…parameters…of…return…air… duct…on…uniformity…distribution…of…temperature…and…humidity…within…the…refrigeration…compartment.…The…results…showed… that, when…the…return…air…duct…parameter(length…×…width…×…height)was…1 500…mm…×…500…mm…×…60…mm, the… temperature…had…the…most…uniformity; when…return…air…duct…parameter…was…1 500…mm…×…800…mm…×…80…mm, the… humidity…had…the…most…uniformity.…Using…weight…comprehensive…value…analysis…integrated…temperature…and…humidity… field…on…a…combination…of…orthogonal…experiment…to…evaluate…the…results…of…the…return…air…duct, the…optimal…combination… of…parameters…was…1 500…mm…×…500…mm…×…60…mm.
View Full Text   View/Add Comment  Download reader